Experimental Assessment of Reinforcement Anchorage in CLT Grooves under Tensile Loading

Sixteen tensile tests examine reinforcement anchorage in cross-laminated timber (CLT) grooves for hybrid-floor continuity connections. Two concrete-groove widths, two epoxy systems and headed-bar pockets with and without screws are compared using peak forces, apparent quasi-linear stiffnesses, force–elongation curves and observed damage. Companion bar tests provide reference forces. Concrete grooves with basic widths of 45 and 55 mm reached mean peak forces of 24.80 and 21.71 kN, respectively, with continued force transfer after cracking. Mean peak forces were 46.71 kN for XEPOX FLUID and 51.89 kN for HIT–RE 500 V4. The Hilti specimens showed plastic deformation of the reinforcement, whereas the XEPOX curves formed two response groups. Two screws increased the headed-pocket peak force from 26.08 to 41.50 kN and altered cracking. HIT–RE 500 V4 and XEPOX FLUID exhibited mean apparent quasi-linear stiffnesses of 8.6 and 7.7 kN/mm, respectively.